This scenario will complete the E2E procedure of PNF in-place SW upgrade case started from Casablanca (evolved in Dublin). The E2E procedure is VID→ SO→ Controller(SDNC/CCSDK)→Ansible Server→ EMS → PNF.
Support LCM API for downloadNESw and activateNESw actions
Provide ansible playbooks for downloadNESw and activateNESw
Since this scenario started from Casanblanca, it is helpful to find more details completed in past releases with following link.
Project/Component | Story |
---|---|
SO | Support generic PNF workflow design |
SO | Support upgrade sw version at PNF instance level |
SO | Align with SO building block for PNF Upgrade procedure 1) Create new SO BB – downloadNESw 2) Create new SO BB – activateNESw 3) Create new SO BB – update AAI 4) Update SO BB – preCheck and postCheck |
SO | Support different controller decision points in SO |
SDNC/CCSDK | Support LCM API for downloadNESw and activateNESw actions |
SDNC/CCSDK | Provide ansible playbooks for downloadNESw and activateNESw |
VNFRQTS | PNF Software Upgrade with ansible with EM |
Integration | 1) EMS simulator extension 2) Integration document revision for PNF Sw Upgrade UC |
- LCM API of CCSDK:
LCM API Abbre. | HTTP Method | URI | Yang Model Section | Request Example | Response Example | |||
---|---|---|---|---|---|---|---|---|
UpgradePreCheck* | POST | /operations/LCM:upgrade-pre-check |
|
| 400: Success
| |||
UpgradePostCheck* | /operations/LCM:upgrade-post-check |
|
| 400: Success
| ||||
DownloadNESw | /operations/LCM:download-n-e-sw |
|
| 400: Success
| ||||
ActivateNESw | /operations/LCM:activate-n-e-sw |
|
| 400: Success
|
*: These LCM APIs are enhanced from R4/R5, and update the vnf-id field in action-identifiers to pnf-name in the request parameter.
The playbook-name in the payload of request is optional. If not set the playbook-name in the request, it will use the value in the config file /opt/onap/sdnc/data/properties/lcm-dg.properties of SDNC.
JIRA Status Tracking
Head Epic :
No | Test Case | Test Status |
---|---|---|
1 | UpgradePreCheck for PNF instance from SDNC to EM using LCM API | COMPLETE |
2 | DownloadNESw for PNF instance from SDNC to EM using LCM API | COMPLETE |
3 | ActivateNESw for PNF instance from SDNC to EM using LCM API | COMPLETE |
4 | UpgradePostCheck for PNF instance from SDNC to EM using LCM API | COMPLETE |
5 | Test PNF SW upgrade Workflow for PNF instance from SO to SDNC (using LCM API) to EM | COMPLETE |
1. Add topics SDNC-LCM-READ and SDNC-LCM-WRITE to DMaaP if they don't exist.
curl -s -H "Content-Type: application/json" -X POST http://message-router.onap:30227/topics/create -d ' { |
curl -s -H "Content-Type: application/json" -X POST http://message-router.onap:30227/topics/create -d ' { "topicName": "SDNC-LCM-WRITE", "partitionCount": "1", "replicationCount": "1" }' |
2. Add the following line in the file in /opt/ansible-server/Playbooks/Ansible_inventory in ansible-server container:
192.168.35.83 ansible_connection=ssh ansible_port=60032 ansible_user=admin ansible_ssh_private_key_file=/home/ansible/.ssh/ems.key |
Where ems.key is the private key of SSH user admin at EMS Simulator.
3. Initial PNF 5gDU0001 entry in AAI:
{ "pnf-name": "5gDU0001", "pnf-id": "5gDU0001", "ipaddress-v4-oam": "192.168.35.83", "sw-version": "v1", "in-maint": false, "resource-version": "1584873329418" } |
Where Sw Version of PNF 5gDU0001 is "v1".
4. Add some entries to SO catalogdb:
use catalogdb; insert into pnf_resource set MODEL_UUID='f50f34be-9aa7-4a03-aa12-fd29e5f27538', MODEL_VERSION='1.0'; insert into pnf_resource_customization set MODEL_CUSTOMIZATION_UUID='c57939f8-ee46-4700-aa3a-60374507d94f', MODEL_INSTANCE_NAME='TestPnf', PNF_RESOURCE_MODEL_UUID='f50f34be-9aa7-4a03-aa12-fd29e5f27538', CONTROLLER_ACTOR='sdnc'; insert into pnf_resource_customization_to_service set SERVICE_MODEL_UUID='296d49aa-236a-4920-a395-5620df09e765', RESOURCE_MODEL_CUSTOMIZATION_UUID='c57939f8-ee46-4700-aa3a-60374507d94f'; insert into workflow (ARTIFACT_UUID, ARTIFACT_NAME, NAME, VERSION, DESCRIPTION, RESOURCE_TARGET, SOURCE) values ('245a0bca-3816-45c6-9270-1de25d27fc56', 'PNFSoftwareUpgrade.bpmn', 'PNFSoftwareUpgrade', '1.0', 'PNF Software Upgrade Test', 'pnf', 'native'); |
Test case ID | 1 | ||||||
---|---|---|---|---|---|---|---|
Name | UpgradePreCheck for PNF instance from SDNC to EM using LCM API | ||||||
Description | UpgradePreCheck for PNF instance from SDNC to EM using LCM API | ||||||
Release | Frankfurt | ||||||
Pre-conditions | |||||||
Testing Steps |
| ||||||
Conclusion (Pass/Fail) | Pass | ||||||
Test Lab |
Test case ID | 2 | ||||||
---|---|---|---|---|---|---|---|
Name | DownloadNESw for PNF instance from SDNC to EM using LCM API | ||||||
Description | DownloadNESw for PNF instance from SDNC to EM using LCM API | ||||||
Release | Frankfurt | ||||||
Pre-conditions | |||||||
Testing Steps |
| ||||||
Conclusion (Pass/Fail) | Pass | ||||||
Test Lab |
Test case ID | 3 | ||||||
---|---|---|---|---|---|---|---|
Name | ActivateNESw for PNF instance from SDNC to EM using LCM API | ||||||
Description | ActivateNESw for PNF instance from SDNC to EM using LCM API | ||||||
Release | Frankfurt | ||||||
Pre-conditions | |||||||
Testing Steps |
| ||||||
Conclusion (Pass/Fail) | Pass | ||||||
Test Lab |
Test case ID | 4 | ||||||
---|---|---|---|---|---|---|---|
Name | UpgradePostCheck for PNF instance from SDNC to EM using LCM API | ||||||
Description | UpgradePostCheck for PNF instance from SDNC to EM using LCM API | ||||||
Release | Frankfurt | ||||||
Pre-conditions | |||||||
Testing Steps |
| ||||||
Conclusion (Pass/Fail) | Pass | ||||||
Test Lab |
Test case ID | 5 | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Test PNF SW upgrade Workflow for PNF instance from SO to SDNC (using LCM API) to EM | ||||||||||||||||
Description | Test PNF SW upgrade Workflow for PNF instance from SO to SDNC (using LCM API) to EM | ||||||||||||||||
Release | Frankfurt | ||||||||||||||||
Pre-conditions | |||||||||||||||||
Testing Steps | NOTE: Befor testing this case, reset the EMS Simulator to initial status.
Retrieve the status of the workflow:
While the requestStatus is "IN_PROGRESS", then wait a minute to retrieve the status of workflow again and agiain, until the requestStatus is "COMPLETED":
While the requestStatus is "COMPLETED", then retrieve the Sw Version of PNF 5gDU0001 in AAI:
The Sw Version of PNF 5gDU0001 in AAI is upgraded to "v2". | ||||||||||||||||
Conclusion (Pass/Fail) | Pass | ||||||||||||||||
Test Lab |