Commissioning dialogues are used to commission and decommission Control Loop Type definitions and to set the values of Common Parameters.
Commissioning a Control Loop Type is a three-step process
- The Control Loop Type must be created, that is the Control Loop Type definition must be loaded and stored in the database. This step may be carried out over the REST interface or using SDC distribution.
- The Common Properties of the Control Loop type must be assigned values and those values must be stored in the database. This step is optional only if all mandatory common properties have default values. The Common Property values may be set and amended over and over again in multiple sessions until the Control Loop Type is primed.
- The Control Loop Type Definition and the Common Property values must be primed, that is sent to the concerned participants. Once a Control Loop Type is primed, its Common Property values can no longer be changed. To change Common Properties on a primed Control Loop Type, all instances of the Control Loop Type must be removed and the Control Loop Type must be de-primed.
1.1 Commissioning a Control Loop Type Definition using the CLAMP GUI
...
1.4 Priming a Control Loop Type Definition on Participants
The Priming operation sends Control Loop Type definitions and common property values to participants. Once a Control Loop Type definition is primed, its property values can on longer be changed until it is de-primed.
PlantUML Macro |
---|
@startuml participant CLAMP_GUI participant CLAMP_Runtime participant Participant database Commissioned_CL_Inventory CLAMP_GUI -> CLAMP_Runtime: [REST] Read Control Loop Type Definitions CLAMP_Runtime -> Commissioned_CL_Inventory: Read Control Loop Type Definitions CLAMP_Runtime -> CLAMP_GUI: [REST] Type Definitions returned CLAMP_GUI -> CLAMP_GUI: Select Control Loop Type Definition for Priming on Participants CLAMP_GUI -> CLAMP_Runtime: [REST] Prime Control Loop Type Definition on Participants alt Control Loop Type Definition not Primed on Participants CLAMP_Runtime -> Commissioned_CL_Inventory: Read Control Loop Type Definition CLAMP_Runtime -> Commissioned_CL_Inventory: Read Common Parameter Values for Control Loop Type Definition alt Common Parameter values set for Control Loop Type Definition CLAMP_Runtime -> Participants: [DMaaP] Update Participants with Control Loop Type Definition and values for Common Parameters CLAMP_Runtime -> CLAMP_GUI: [REST] Control Loop Type Definition priming ordered on participants else Control Loop Type Definition already primed on Participants CLAMP_Runtime -> CLAMP_GUI: [REST] Common Parameters not set\non Control Loop Type Definition end else Control Loop Type Definition already primed on Participants CLAMP_Runtime -> CLAMP_GUI: [REST] Cannot set Common Parameters on\nControl Loop Type Definition that has\nbeen primed on participants end == Participant Responses == Participants -> CLAMP_Runtime: [DMaaP] Result of Update with Control Loop Type Definition and values for Common Parameters CLAMP_Runtime -> Commissioned_CL_Inventory: Store result of Control Loop Type Definition Update on Participant == Supervision == loop forever CLAMP_Runtime -> Commissioned_CL_Inventory: Read Control Loop Type Definitions loop over each Control Loop Type Definition alt Control Loop Type Definition Participant priming underway CLAMP_Runtime -> Commissioned_CL_Inventory: read result of Control Loop Type Definition Updates from participants alt Updates completed on all participants CLAMP_Runtime -> Commissioned_CL_Inventory: set Control Loop Type Definition as primed on Participants else Updates not completed alt Priming of Control Loop Type Definition on participants timed out CLAMP_Runtime -> Commissioned_CL_Inventory: set Control Loop Type Definition priming as timed out on Participants CLAMP_Runtime -> CLAMP_Runtime: Log error else Wait for updates to complete end end else Control Loop Type Definition Participant priming not underway end end end @enduml |
...