Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

    • Epic and Use Stories
    • VNFM Adapter Design
    • SOL001/SOL004 Support & Design
    • SO BPMN Infra & VNFM Adapter Run-time Scenario
    • SOL003 API Support
    • SO VNFM Adapter SOL003 API Support Design
    • VNFM Adapter VNF Package Management (Not part of Dublin)
    • SDNC Assignment Management
    • VNFM Adapter Locating SVNFM
    • VNF Life-cycle Granting
    • VNFM Adapter Homing Decision for VNF Granting (TBD)
    • SVNFM Simulator


  • Epic


EpicFeatureDescription

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1508

ETSI Alignment - SO SOL003 plugin support to connect to external VNFMs


ETSI Alignment - SO SOL003 plugin support to connect to an external VNFM. 

  • Leverage ETSI standards for VNF LCM in SO
  • Build SO VNFM Adapter
    • Use SOL003 APIs (2.5.1) for VNF LCM
    • Support operations such as create, instantiate, grant, query, terminate/delete, LCN subscription, LCN and VNF package management
    • Support of Delete VNF is a stretch goal in Dublin
  • Enhance SO BPMN workflows & recipes
    • VNF-level and VF-Module workflows, leveraging VNFM Adapter 
    • Passing VNF LCM requests to VNFM using VNFM Adapter
  •  Provide VNF package management for VNFM (Stretch Goal; under investigation)


  • User Stories


User StoriesFeatureDescription

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1538

Create the Functional test case to validate VNFM Adapter NBI and SOL003-based SBIValidate VNFM Adapter NBI and SOL003-based SBI

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1618

SVNFM Simulator

For integration testing in ONAP, vendor-neutral SVNFM is needed, 

This SVNFM Simulator supports SOL003-based interfaces and message exchange sequences for interface verification.

  • vCPE VNF packages plan to be used for this validation testing.

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1619

Create SO VNFM Adapter Northbound Interface using SwaggerCreate SO VNFM Adapter Northbound Interface using Swagger

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1620

Create Shell Adapter
  • Deployable VNFM Adapter container in ONAP (including docker image and helm chart)
  • Register VNFM Adapter with MSB

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1621

Create placeholder implementation for create VNF (without SVNFM interaction)
  • Create Override YAML in OOM project
  • Define Create/instantiate VNF interface which log the request in SVNFM adapter
  • Create request to VNFM adapter for VNF creation

Note: manual database update to trigger new BB flow and no pre-load

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1622

Check for existing VNF (with SVNFM Interaction)
  • Update Override YAML to add A&AI basic auth and URL
  • Generate 003 APIs using swagger
  • Get the generic-vnf from A&AI
  • Select a VNFM from A&AI (if not already associated with a VNFM)
  • Check for existing VNF

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1623

Handle Create VNF request in VNFM adapter
  • Get VNFD Id from original csar
  • Send create request to the SVNFM
  • Set self-link based on result of create operation

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1624

Instantiate VNF (with SVNFM Interaction)
  • With pre-load data from SDNC based on model name and VNF-type
  • Get the flavor Id from the CSAR
  • Get the VIM info from A&AI
  • Send request to SVNFM
  • Update generic-vnf orchestration status A&AI

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1625

Handle Grant Request (Without Homing/OOF)Reply to grant request based on given VIM info in request

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1626

Monitor Job Status

Monitor Job Status

  • Adapter Store and return job Id ( job ids stored in cache)
  • Introduce Job monitoring handling in flow
  • Handle time out for Job monitoring ( hard coded/configure in yaml timeout)
  • Identify the VNFM and operation Id for the job
  • Send get operation status request to VNFM
  • Return status

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1627

Create relationship between esr-vnfm and generic-vnf in AAI

Create relationship between esr-vnfm and generic-vnf in AAI

  • add a rule to AAI DBEdgeRule ESR
{ "from": "generic-vnf", "to": "esr-vnfm", "label": "tosca.relationships.DependsOn", "direction": "OUT", "multiplicity": "MANY2ONE", "contains-other-v": "NONE", "delete-other-v": "NONE", "prevent-delete": "NONE", "default": "true", "description":"" }
  • read the relationship in the SO VNFM Adapter Adapter

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1628

Handle Notification Subscription

Notification Subscription

  • Update generic-vnf status
  • Create vServers
  • Set OAM IP address - source of which needs to be configurable
  • Update Orch status in A&AI to completed

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1629

Notification Handling - Instantiate

Notification Handling - Instantiate

  • Update generic-vnf status
  • Create vServers
  • Set OAM IP address - source of which needs to be configurable
  • Update Orch status in A&AI to completed

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1630

Monitor Node Status

Monitor Node Status

  • Introduce Node monitoring handling in flow which periodically check orchestration status in A&AI
  • Handle time out for node status handling (hard coded/configurable timeout)

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1631

Handling Homing in FlowHandling Homing in Flow

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1632

Handle VNF delete and termination (without SVNFM integration)

Deleting/Terminating VNF (without SVNFM integration)

  • Define Terminate/Delete VNF interface in VNFM adapter
  • Update or introduce new building block which invoke VNFM adapter for termination

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1633

Terminate VNF (with SVNFM interaction)

Terminate VNF (with SVNFM interaction)

  • Identify the SVNFM to use from A&AI
  • Send terminate request to SVNFM
  • Send delete request to SVNFM
  • Return a job Id
  • Check termination job status in flow

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1634

Notification Handling - Terminate

Notification Handling - Terminate

  • Delete vServers
  • Update generic-vnf orchestration status
  • Check node termination status in flow

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1635

Remove SDNC pre-load and introduce user_param handling

Remove SDNC pre-load and introduce user_param handling

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1636

Handle Failure case where notification is missed (Query VNF)

Handle Failure case where notification is missed (Query VNF)

  • VNFM Adapter expose interface to get of VNF info
  • Flow use VNF info to check status at timeout

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keySO-1637

Spike - investigate OAM IP address handling for generic-vnf

Investigate OAM IP Address handling for generic-vnf

...

Gliffy Diagram
nameSO VNFM Adapter High Level Flow Design
pagePin14


    1. SO BPMN Service workflows dispatch new resource-level workflows based on VNF request parameters (e.g., type, others).
      1. Once a Service workflow chooses a new workflow path for VNFM Adapter, the subsequent requests for the same VNF will follow the new path.
      2. an association between VNF and VNFM will be made in A&AI.
    2. SO BPMN VNF-level resource workflows handle:
      1. Assign VNF to SDNC
      2. Retrieve the VNF Assignment from SDNC
      3. Invoke VNFM Adapter Client with required parameters
    3. VNFM Adapter Client manages:
      1. Populate parameter structures based on data from SO workflows
      2. Invoke VNFM Adapter NBI with required parameters
    4. VNFM Adapter gets GenericVNF from A&AI
    5. VNFM Adapter locates the corresponding VNF and VNFM registration info form A&AI (ESR). Two methods are suggested
      1. Current one: based on VNF NF Type and VNFM Type in A&AI
      2. Could use VNFD vnfm_info:type, VNFM registration values: VNFM type, Cloud Region, vendor - logic is being designed
    6. VNFM Adapter gets VimConnectionInfo from A&AI
      1. Queries A&AI based on the cloud region and tenant id
      2. Builds the VimConnectionInfo based on the type, service-url, user-name, password, cloud-domain, etc.
    7. VNFM Adapter uses network assignment (e.g., IP Address) from SO (thru SDNC) and builds the extVirtualLinks and other parameters.

...