Use Cases
VNF Configuration (Ve-Vnfm-em)
As part of VNF instantiation/heal/scaleOut VNFM can Set VNF initial configuration using SOL002 VNF Configuration interface towards EM (ONAP).
SOL002 Adapter can convert this configuration to another protocol and ONAP Controller enables Operator configurability.
VNF LCM (Ve-Vnfm-em)
VNF Indicator Interface (Ve-Vnfm-em)
ETSI-Alignment SOL002 Adapter Use Cases
- VNF LCM (Ve-Vnfm-em). ONAP as EM role.
- Application configuration
- Option 1: VNFM initiated: Application configuration (Ve-Vnfm-em). ONAP as EM role.
- Option 2: Through LCM notifications subscribed with VNF LCM interface, SOL002 Adapter can execute wanted configuration.
- Enable VNFM to subscribe Indicator notifications through VND indicator interface.
- Security between Adapter and VNFM (not sol002 adapter alone, but same code/mechanism should be used as other adapters)
- Application configuration (Ve-Vnfm-vnf). ONAP as VNFM role. (Stretch goal)
Feature Descriptions
Feature | Description |
---|---|
SOL002 Adapter to execute VNF LCM operations towards VNFM (Ve-Vnfm-em) | |
SOL002 Adapter to subscribe VNF LCM notifications from VNFM to enable ONAP operations (VNF configuration, CLoseLoop termination etc.) | |
SOL002 Adapter application configuration (Ve-Vnfm-em) by VNFM | SOL002 Adapter exposes configuration endpoint for external VNFM:
|
SOL002 Adapter enables VNFM to subscribe to VNF indicator notifications by VNFM and send indicator notifications to VNFM (Ve-Vnfm-em) | |
SOL002 Adapter application configuration (Ve-Vnfm-vnf) (Stretch goal) | SOL002 Adapter exposes West-bound interface to any ETSI-aligned VNF. SOL002 Adapter utilizes configuration call towards ETSI-aligned VNF:
|
Epic and User Story
Epic | User Story | Description | Is Frankfurt? |
---|---|---|---|
SOL002 Adapter | SOL002 Adapter exposes its East-bound interface to any VNFM Adapter Client. | ||
SOL002 Adapter exposing EBI interface: | |||
| SOL002 Adapter supports configuration call for a VNF level | yes | |
| SOL002 Adapter supports configuration call for a VNFC level | yes | |
| SOL002 Adapter to subscribe VNF LCM notifications from VNFM to enable ONAP operations | yes | |
| SOL002 Adapter supports indicator interface to in order to support Policy-based scaling - TBD | ? | |
SOL002 Adapter exposing WBI interface: | |||
| SOL002 Adapter exposes West-bound interface to any ETSI-aligned VNF | Stretch goal |
SOL002 Adapter Architecture
<describe architecture, design...>
SOL002 Operations
The following SOL002 operations will be supported:
API Action | Actor | Method | URI | Description |
---|---|---|---|---|
Application Configuration | VNFM → SOL002 Adapter | PATCH | /configuration | To configure |
SOL002 Operation Sequence Flows
<Input from Samsung>