Test Case IdV00009
Test Case NamevIMS Service Creation
DescriptionThis test creates vIMS service
ReleaseAmsterdam
Preconditions
  1. All vIMS VNFD csar files can pass VNFSDK checking
  2. All vIMS VNFs have been onboarded
  3. All VNFs images files have been uploaded manually into ONAP
Testing Steps
  1. In SDC create vIMS service with the following VNFs
    1. vPCSCF
    2. vI/SCSCF
    3. vTAS
  2. As part of vIMS service composition, create Virtual Links (VL) to connect the VNFs together according to vIMS service design
Expected Results
  1. vIMS service is created successfully
  2. vnfmInfo is correctly pointed to vendor's SVNFM
  3. vIMS service is successfully stored in catalog
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00010: WAN Service Creation (need update - WAN service Resource Onboarding (WAN resource only has properties , but keep in template, need to confirm overlay and underlay services are seperate ?resources)

Test Case IdV00010
Test Case NameWAN Service CreationResource Onboarding
DescriptionThis test creates onboards WAN service resource using SDC
ReleaseAmsterdam
Preconditions
  1. WAN underlay network template has been defined and packaged in a CSAR file
  2. WAN overlay network template has been defined and packaged in a CSAR file
  3. All PNFs (PE, DC gateway) resources have been defined in SDC
  4. All required network connection types (VLAN, BGP MPLS L3VPN, VXLAN, etc) are defined in SDC
Testing Steps
  1. In SDC create a new WAN service
  2. In service composition, pull in 2 PE routers, namely PE1 and PE2
  3. In service composition, pull in 2 data center gateways, namely DC GW1 and DC GW2
  4. Create underlay network as following:
    1. DC GW1 → PE1 as vlan
    2. DC GW2 → PE2 as vlan
    3. PE1 → PE2 as BGP MPLS L3VPN
  5. onboard WAN underlay network CSAR file
  6. In SDC onboard WAN overlay network CSAR fileCreate overlay network DC GW1 → DC GW2 as VXLAN
Expected Results
  1. Underlay WAN underlay network created resource onboarded successfullyOverlay
  2. WAN overlay network created resource onboarded successfully
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name

...

V00014: System Performance and Alarm Monitoring

Test Case IdV00014
Test Case NameSystem Performance and Alarm Monitoring
DescriptionThis test uses Usecase UI GUI to monitor system performance and event
ReleaseAmsterdam
Preconditions
  1. VoLTE service has been instantiated
  2. Closed loop for VoLTE has been configured and started
Testing Steps
  1. ONAP user uses Usecase UI GUI to check system performance, such as CPU, memory and disk usage
  2. ONAP user views the VNF alarms collected by ONAP
Expected Results
  1. System performance (including system CPU, memory and disk usage) is shown on ONAP Usecase UI GUI
  2. VNF alarms, specified in CLAMP for the closed loop, are shown in Usecase UI GUI
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


Category: Closed Loop


V00015: VoLTE Auto-healing

...