  1. APPC and MultiCloud located the problem to be API call request prefix. Bin Yang provided the following sample code to call MultiCloud API to do VM restart. APPC will fix the problem accordingly.

    Info
    export MULTICLOUD_PLUGIN_ENDPOINT=http://10.0.14.1:9005/api/multicloud-titanium_cloud/v0/pod25_RegionOne export TOKEN=$(curl -v -s -H "Content-Type: application/json" -X POST -d '{ }' $MULTICLOUD_PLUGIN_ENDPOINT/identity/v3/auth/tokens 2>&1 | grep X-Subject-Token | sed "s/^.*: //") export PROJECT_ID=466979b815b5415ba14ada713e6e1846 curl -v -s -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X GET $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers curl -v -s -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X POST -d '{"os-stop":null}' $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers/0a06842a-4ec4-4918-b046-399f6b38f5f9/action curl -v -s -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X POST -d '{"os-start":null}' $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers/0a06842a-4ec4-4918-b046-399f6b38f5f9/action

10/17/2017

  1. APPC has made good progress to fix a few bugs. The execution has reached MultiCloud API. A call is set up on 10/18 to look into this problem with MultiCloud people.

10/16/2017

  1. DCAE to Policy: Vijay Venkatesh Kumar has fixed TCA policy to put in the correct closed loop name. However, multiple problems exist in the TCA output, tracked by 
    Jira
    serverONAP JIRA
    columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
    serverId425b2b0a-557c-3c0c-b515-579789cceedb
    keyDCAEGEN2-164
    .
    1. Fixed vCPE policies on the wiki to use VNF as the controlLoopSchemaType. 
    2. Fixed TCA jar to include "version" as is needed by Policy.
  2. Passed test: → DCAE → Policy → . Manually fed a VES data to DCAE, observed an event from Policy to APPC.
    1. Note that currently Policy does not check the time stamp in the event so for testing purpose there is no need to increase the time stamp in the VES data.
    2. Once Policy sends out a
  3. DCAE to Policy: Vijay Venkatesh Kumar has fixed TCA policy to put in the correct closed loop name. However, multiple problems exist in the TCA output, tracked by 
    Jira
    serverONAP JIRA
    columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
    serverId425b2b0a-557c-3c0c-b515-579789cceedb
    keyDCAEGEN2-164
    .
    1. Fixed vCPE policies on the wiki to use VNF as the controlLoopSchemaType. 
    2. Fixed TCA jar to include "version" as is needed by Policy.
  4. Passed test: → DCAE → Policy → . Manually fed a VES data to DCAE, observed an event from Policy to APPC.
    1. Note that currently Policy does not check the time stamp in the event so for testing purpose there is no need to increase the time stamp in the VES data.
    2. Once Policy sends out a restart event to APPC, it will not send another restart event until the current operation is completed or time expires even if it receives subsequent ONSET events. To retest in case operation fails in APPC, Policy needs to be restarted.
  5. Eric Multanen has fixed the even data content problem to include the correct vnf_id passed from the HEAT. See details appended by Eric to to 10/13/2017 notes.

...

  1. Design and load policy rules to policy engine. Ideally this should be done by CLAMP. Currently CLAMP is working on

    Jira
    serverONAP JIRA
    columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
    serverId425b2b0a-557c-3c0c-b515-579789cceedb
    keyCLAMP-59
    . The workaround is to use Policy GUI. Jorge Hernandez will work on this.

  2. Preload AAI with vCPE data. The purpose is to lookup vServer using vGMUX VNF ID. Scott Seabolt (APPC) will provide a sample data to Venkata Harish Kajur (AAI) to show the named query. Venkata Harish Kajur will then create a script to preload such data to AAI for the testing.

  3. vGMUX sends packet loss VES to DCAE VES collector.

    • Kang Xi created a vGMUX instance in the open lab but the VPP-based VNF inside the VM is not functioning. According to Eric Multanen, most likely it is caused by network issues. Eric is working on this. Kang will also inform Danny Zhou and Johnson Li about this.

    • The following VES data caused an error. The most possible reason is that the data itself is incorrect. Vijay Venkatesh Kumar is looking into that.

      Code Block
      languagebash
      titleVES Data
      curl -H "Accept: application/json" -H "Content-Type: application/json" -d '{"event":{"measurementsForVfScalingFields":{"measurementInterval":10,"measurementsForVfScalingVersion":1.1,"vNicUsageArray":[{"multicastPacketsIn":0,"bytesIn":4300,"unicastPacketsIn":0,"multicastPacketsOut":0,"broadcastPacketsOut":0,"packetsOut":0,"bytesOut":0,"broadcastPacketsIn":0,"packetsIn":101,"unicastPacketsOut":0,"vNicIdentifier":"eth1"}]},"commonEventHeader":{"reportingEntityName":"zdfw1fwl01fwl01","startEpochMicrosec":1500379662497999,"lastEpochMicrosec":1500379672497999,"eventId":"1","sourceName":"zdfw1fwl01fwl01","sequence":1,"priority":"Normal","functionalRole":"vFirewall","domain":"measurementsForVfScaling","reportingEntityId":"No UUID available","sourceId":"75ec15e4-1a9a-4ee3-bb3c-31556903558d","version":1.2}}}' 10.12.25.84:8080/eventListener/v5
      
      
    DCAE TCA sends an event to Policy through DMaaP. This is tested as described in 
    • curl -H "Accept: application/json" -H "Content-Type: application/json" -d '{"event":{"measurementsForVfScalingFields":{"measurementInterval":10,"measurementsForVfScalingVersion":1.1,"vNicUsageArray":[{"multicastPacketsIn":0,"bytesIn":4300,"unicastPacketsIn":0,"multicastPacketsOut":0,"broadcastPacketsOut":0,"packetsOut":0,"bytesOut":0,"broadcastPacketsIn":0,"packetsIn":101,"unicastPacketsOut":0,"vNicIdentifier":"eth1"}]},"commonEventHeader":{"reportingEntityName":"zdfw1fwl01fwl01","startEpochMicrosec":1500379662497999,"lastEpochMicrosec":1500379672497999,"eventId":"1","sourceName":"zdfw1fwl01fwl01","sequence":1,"priority":"Normal","functionalRole":"vFirewall","domain":"measurementsForVfScaling","reportingEntityId":"No UUID available","sourceId":"75ec15e4-1a9a-4ee3-bb3c-31556903558d","version":1.2}}}' 10.12.25.84:8080/eventListener/v5
      
      
  4. DCAE TCA sends an event to Policy through DMaaP. This is tested as described in 

    Jira
    serverONAP JIRA
    columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
    serverId425b2b0a-557c-3c0c-b515-579789cceedb
    keyDCAEGEN2-124

  5. Policy process the event from DCAE, and then sends a “restart” event to APPC through DMaaP. Jorge Hernandez will work on this.

  6. APPC captures the event from Policy, performs a named query to AAI to get the vServer ID based on the VNF ID, and then restarts the VM through MultiVIM. 

    • APPC is working on some changes and will be able to test next week. 
    • There should be a MultiVIM VM in the stack but we don't see any. Refer
      Jira
      serverONAP JIRA
      columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
      serverId425b2b0a-557c-3c0c-b515-579789cceedb
      key

...

Policy process the event from DCAE, and then sends a “restart” event to APPC through DMaaP. Jorge Hernandez will work on this.

...

APPC captures the event from Policy, performs a named query to AAI to get the vServer ID based on the VNF ID, and then restarts the VM through MultiVIM. 

    • INT-258
       to track this problem.

In addition, the bottom of Policy R1 Amsterdam Functional Test Cases shows important sample data for vCPE test cases.

Update:

  • Scott Seabolt created the data pertaining to the vGMUX in POD25 which needs to be inventoried in POD25 A&AI. Venkata Harish Kajur then created a script to preload AAI with the following instructions: "Unzip this closed-loop.zip and go into closed-loop directory and run the ./put_closed_loop.sh ${AAI_VM1_IP_ADDRESS} And then you can verify that it works by doing a ./verify.sh ${AAI_VM1_IP_ADDRESS} and it should return you that named query response that you sent me."
  • Meeting recording

Related Documents:

  1. VNF Doc: ONAP vCPE VNF Installation Guide v1.docx
  2. DCAE mS Deployment (Standalone instantiation)


export MULTICLOUD_PLUGIN_ENDPOINT=http://10.0.14.1:9005/api/multicloud-titanium_cloud/v0/pod25_RegionOne

 

export TOKEN=$(curl -v -s -H "Content-Type: application/json" -X POST -d '{ }'  $MULTICLOUD_PLUGIN_ENDPOINT/identity/v3/auth/tokens 2>&1 | grep X-Subject-Token | sed "s/^.*: //")

 

export PROJECT_ID=466979b815b5415ba14ada713e6e1846

 

curl -v -s  -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X GET $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers

 

curl -v -s -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X POST -d '{"os-stop":null}'  $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers/0a06842a-4ec4-4918-b046-399f6b38f5f9/action

 

curl -v -s -H "Content-Type: application/json" -H "X-Auth-Token: $TOKEN" -X POST -d '{"os-start":null}'  $MULTICLOUD_PLUGIN_ENDPOINT/compute/v2.1/$PROJECT_ID/servers/0a06842a-4ec4-4918-b046-399f6b38f5f9/action

    • APPC is working on some changes and will be able to test next week. 
    • There should be a MultiVIM VM in the stack but we don't see any. Refer
      Jira
      serverONAP JIRA
      columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
      serverId425b2b0a-557c-3c0c-b515-579789cceedb
      keyINT-258
       to track this problem.

In addition, the bottom of Policy R1 Amsterdam Functional Test Cases shows important sample data for vCPE test cases.

Update:

  • Scott Seabolt created the data pertaining to the vGMUX in POD25 which needs to be inventoried in POD25 A&AI. Venkata Harish Kajur then created a script to preload AAI with the following instructions: "Unzip this closed-loop.zip and go into closed-loop directory and run the ./put_closed_loop.sh ${AAI_VM1_IP_ADDRESS} And then you can verify that it works by doing a ./verify.sh ${AAI_VM1_IP_ADDRESS} and it should return you that named query response that you sent me."
  • Meeting recording

Related Documents:

...