The bulk PM feature consists of two main parts:

  • Event-driven bulk transfer of monitoring data from an xNF to ONAP/DCAE. A micro-service will listen for 'FileReady' VES events sent from an xNF via the VES collector. Once files become available the collector micro-service will fetch them using protocol such as FTPES (committed) or HTTPS. The collected data files are published internally on a DMaaP Data Router (DR) feed.
  • For 3GPP formatted measurement data and for consumers that prefer such data in VES format, an optional 3GPP PM Mapper micro-service is planned that can extract selected measurements from a 3GPP XML file and publish them as VES events on a DMaaP Message Router topic. The mapper receives the files by subscribing to a Data Router feed.

Presentations:

Development Status

ProjectPTLJIRADescription
DCAE

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyDCAEGEN2-566

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyDCAEGEN2-567

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyDCAEGEN2-564

  1. Develop new file collector micro-service
  2. Develop new 3GPP PM mapper micro-service (stretch goal)
  3. Upgrade VES collector to support VES version 6.0 and new notification domain (dependency)
DMaaPRamprasad Koya

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyDMAAP-28

  1. Integrate Data Router service (under investigation, not committed)
VNFRQTS

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyVNFRQTS-263

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyVNFRQTS-264

  1. Add general xNF requirements for bulk file transfer mechanism
  2. Add xNF requirements for transfer of bulk PM data in 3GPP format

Testing

Current Status

  1. Testing Blockers

  2. High visibility bugs
  3. Other issues for testing that should be seen at a summary level
  4. Where possible, always include JIRA links


End to End flow to be Tested:  DCAE Data File Collector



End to End flow to be Tested:  DCAE 3GPP PM Mapper

Gliffy Diagram
size550500
nameSummary SeqDia Template
pagePin2
version6


Gliffy Diagram
size550500
nameSummary SeqDia Template
pagePin2

Test Cases and Status:  DCAE Data File Collector

#Test CaseStatus
1xNF:  Ensure fileReady event is received from xNF at DCAE VES collector.

Status
titleNot yet tested

2DCAE VES Collector:  Ensure fileReady event is processed and forwarded to correct topic on DCAE Message Router.

Status
titleNot yet tested

3
DCAE File Collector:  Ensure fileReady event is received from DCAE Message Router.

Status
titleNot yet tested

DCAE File Collector:  Ensure event is processed and connection to file location is initiated for file retrieval.

Status
titleNot yet tested

DCAE File Collector:  Ensure that for each new entry in the fileReady event the file is retrieved.

Status
titleNot yet tested

6DCAE File Collector:  Ensure the connection is closed.

Status
titleNot yet tested

7DCAE File Collector:  Ensure the data file(s) retrieved for that processed fileReady event are published to correct feed on DMaaP Data Router.

Status
titleNot yet tested
 


Q:  Should we need separate test cases for validation and error handling scenario?  Or just include in above as exceptions per test case?


Test Cases and Status:  DCAE 3GPP PM Mapper

#Test CaseStatus
1

Status
titleNot yet tested

2

Status
titleNot yet tested

3

Status
titleNot yet tested


Status
titleNot yet tested
 


Status
titleNot yet tested
 

6

Status
titleNot yet tested

7

Status
titleNot yet tested