- Support for vFW use case
- Multi-Cloud API changes with oof_directives and sdnc_directives.
- Multi-Cloud preparing HEAT parameters from oof_directives and sdnc_directives
- SRIOV-NIC feature
- Region selection based on score
Scenario:
- ONAP managing 3 cloud-regions.
...
- Cloud-region1, Cloud-region2 and Cloud-region3
- All cloud regions are controlled by Openstack (with HEAT service)
- Each cloud-region has three flavors
- Cloud-region1:
- Flavor 11:
- 2 vcpus, 8 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 4
- Flavor 12:
- 2 vcpus, 12 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 6
- SRIOV-NIC with PCI Vendor:
...
- 8086 and PCI device :
...
- 154C on physical network 1(
...
- shared-1) with support for
...
- 3VFs
- Flavor 13:
- 2 vcpus, 12 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 6
- SRIOV-NIC with PCI Vendor:
...
- 8086 and PCI device :
...
- 154C on physical network
...
- 2(private-1) with support for 1VFs
- Cloud-region2 :
- Flavor 21:
- 2 vcpus, 8 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 4
- SRIOV (non-NIC) ( with PCI vendor:
...
- 8086 Device ID:
...
- 0443 Count as 2. (alias={"name":"qat-dh895xcc-vf","product_id":"0443","vendor_id":"8086"})
- Flavor 22:
- 2 vcpus, 12 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 6
- SRIOV-NIC with PCI Vendor:
...
- 8086 and PCI device :
...
- 154C on physical network 1 (
...
- shared-1) with support for 2VFs
- Flavor 23:
- 2 vcpus, 12 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 6
- SRIOV-NIC with PCI Vendor:
...
- 8086 and PCI device :
...
- 154C on physical network
...
- 2(private-1) with support for
...
- 2VFs
- Cloud-region3:
- Flavor 31:
- 2 vcpus, 8 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 4
- SRIOV (non-NIC) with PCI vendor:
...
- 8086 Device ID:
...
- 37c9 Count as 2. (alias={"name":"qat-c62x-vf","product_id":"37c9","vendor_id":"8086"})
- Flavor 32:
- 2 vcpus, 8 Gbytes of memory, 20Gb disk
- Numa page size: 1Gbytes and number pages 8
- Flavor 33:
- 2 vcpus, 12 Mbytes of memory, 20Gb disk
- Numa page size: 2Mbytes and number pages 6
- SRIOV-NIC with PCI Vendor:
...
- 8086 and PCI device :
...
- 154C on physical network 1(
...
- shared-1) with support for 1VFs
- Test 1 (Basic)
- Scenario:
- Use vFW VNF (firewall, generator and sink)
- firewall part of policy asking for:
- Mandatory:
- 2 vcpus
- 8Mbytes of memory
...
- 10Gbytes of disk
- Numa page size : 2Mbytes and pages 4
- Optional:
- SRIOV PCI vendor
...
- 8086 and device ID
...
- 37c9 with PCI count 1 with score 100
- Generator part of policy asking for:
- Mandatory;
- 1 vcpu
- 7Gbytes of memory
...
- 10Gbytes of disk
- No Numa
- No optional
- Sink part of policy asking for:
- No mandatory
- No optional
- Modify vFW HOT templates with right label and ensure that those labels are referred in the policy properly.
- Instantiate the VNF
- Check for results:
- It would have selected Cloud-region3 with flavor31 for firewallVM, flavor32 for for generator and any flavor for sink.
- Why region 3: Since only Flavor32 has 8Gbytes of memory that can match Generator policy requirements.
- Test 2: (to test SRIOV-NIC feature) (to ensure that right cloud-region is selected based on score)
- Scenario:
- Use vFW VNF (firewall, generator and sink)
- Say
...
- vFW and sink are connected
...
- together on private-1
- firewall part of policy asking for:
- Mandatory:
- SRIOV-NIC vendor
...
- 8086,
...
- 154C device ID on
...
- private-1, count 1
- Generator part of policy asking for:
- Mandatory;
- SRIOV-NIC vendor
...
- 8086,
...
- 154C device ID on
...
- shared-1, count
...
- 3
- Sink part of policy asking for:
...
- Mandatory
- SRIOV-NIC vendor
...
- 8086,
...
- 154C device ID on
...
- private-1, count 1
- No optional
- Modify vFW HOT templates with right label and ensure that those labels are referred in the policy properly.
- Instantiate the VNF
- Check for results:
- It would have selected Cloud-region1 with flavor13 for firewallVM, flavor12
...
- for generator and flavor13 for sink.
- Why region 1: only cloud region one has support for 3 SRIOV-NIC vfs
• Test
...
3 (to ensure that right cloud-region is selected based on score)
- Scenario:
- Use vFW VNF (firewall, generator and sink)
- firewall part of policy asking for:
- Mandatory:
- 2 vcpus
- 8Mbytes of memory
...
- 10Gbytes of disk
- Numa page size : 2Mbytes and pages 4
- Optional:
- SRIOV
...
- -NIC vendor 8086, 154C device ID on shared-1, count 1 - score 100
- Generator part of policy asking for:
- Mandatory;
- 1 vcpu
...
- 10Gbytes of disk
- 2Gbytes of memory
- optional
- >=1Gbytes of Numa page size with Numa count 2 - score 200
- Sink part of policy asking for:
- No mandatory
- No optional
- Modify vFW HOT templates with right label and ensure that those labels are referred in the policy properly.
- Instantiate the VNF
- Check for results:
- It would have selected Cloud-region3 with
...
- flavor33 for firewallVM, flavor32 for
...
- generator and any flavor for sink.
- Why region 3: Since only Flavor32 has
...
- 1Gbyte of NUMA pages and the total score is 300
...
Test Plan 2
This test plan covers the tests related to testing
...