  • Cloud-region2 :
    • Flavor 21:
      • 2 vcpus, 8 Mbytes of memory, 20Gb disk
      • Numa page size: 2Mbytes and number pages 4SRIOV (
      • non-NIC)  ( with PCI vendor: 8086 Device ID: 0443 Count as 2. (alias={"name":"qat-dh895xcc-vf","product_id":"0443","vendor_id":"8086"})Cpu thread policy=isolate and cpu pinning policy is dedicated
    • Flavor 22:
      • 2 vcpus, 12 Mbytes of memory, 20Gb disk
      • Numa page size: 2Mbytes and number pages 6
      • SRIOV-NIC with PCI Vendor: 8086 and PCI device :154C on physical network 1 (shared-1) with support for 2VFs
    • Flavor 23:
      • 2 vcpus, 12 Mbytes of memory, 20Gb disk
      • Numa page size: 2Mbytes and number pages 6
      • SRIOV-NIC with PCI Vendor: 8086 and PCI device :154C on physical network 2(private-1) with support for 2VFs

...

  • Cloud-region3:
    • Flavor 31:
      • 2 vcpus, 8 Mbytes of memory, 20Gb disk
      • Numa page size: 2Mbytes and number pages 4SRIOV (
      • non-NIC) with PCI vendor: 8086 Device ID: 37c9 Count as 2. (alias={"name":"qat-c62x-vf","product_id":"37c9","vendor_id":"8086"})Cpu thread policy=isolate and cpu pinning policy is dedicated
    • Flavor 32:
      • 2 vcpus, 8 Gbytes of memory, 20Gb disk
      • Numa page size: 1Gbytes and number pages 8
    • Flavor 33:
      • 2 vcpus, 12 Mbytes of memory, 20Gb disk
      • Numa page size: 2Mbytes and number pages 6
      • SRIOV-NIC with PCI Vendor: 8086 and PCI device :154C on physical network 1(shared-1) with support for 1VFs

...

  • Test 1 (Basic)
    • Scenario:
      • Use vFW VNF (firewall, generator and sink)
      • firewall part of  policy asking for:
        • Mandatory:
          • 2 vcpus
          • 8Mbytes of memory
          • >=10Gbytes of disk
          • Numa page size : 2Mbytes and pages 4
        • Optional:
          • SRIOV PCI vendor 8086 and device ID 37c9 with PCI count 1 with score dedicated cpu pinning and policy and isolated cpu thread policy with score of 100
      • Generator part of policy asking for:
        • Mandatory;
          • 1 vcpu
          • 7Gbytes of memory
          • >=10Gbytes of disk
          • No Numa
          • No optional
      • Sink part of policy asking for:
        • No mandatory
        • No optional
    • Modify vFW HOT templates with right label and ensure that those labels are referred in the policy properly.
    • Instantiate the VNF
    • Check for results:
      • It would have selected Cloud-region3 with flavor31 for firewallVM, flavor32 for for generator and any flavor for sink.
      • Why region 3:  Since only Flavor32 has 8Gbytes of memory that can match Generator policy requirements .and only flavor31 has cpu thread policy of isolated and cpu pinning policy of dedicated 



  • Test 2:  (to test SRIOV-NIC feature) (to ensure that right cloud-region is selected based on score)
    • Scenario:
      • Use vFW VNF (firewall, generator and sink)
      • Say vFW and sink are connected together on private-1
      • firewall part of  policy asking for:
        • Mandatory:
          • SRIOV-NIC vendor 8086, 154C device ID on private-1, count 1
      • Generator part of policy asking for:
        • Mandatory;
          • SRIOV-NIC vendor 8086, 154C device ID on shared-1, count 3
      • Sink part of policy asking for:
        • Mandatory
          • SRIOV-NIC vendor 8086, 154C device ID on private-1, count 1
        • No optional
    • Modify vFW HOT templates with right label and ensure that those labels are referred in the policy properly.
    • Instantiate the VNF
    • Check for results:
      • It would have selected Cloud-region1 with flavor13 for firewallVM, flavor12 for generator and flavor13 for sink.
      • Why region 1: only cloud region one has support for 3 SRIOV-NIC vfs

...