Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

BBS Properties Use Case ReferenceA&AI Implementation DecisionA&AI Schema ImpactPossible Future Work
RG MAC Address

Metadata Entry

(under HSIA CFS Service Instance)


CPE PNF object relates to it

Internet Profile Generic-VNF relates to it

Metadatum EdgeRules only
Service Type

Metadata Entry

(under HSIA CFS Service Instance)


Access Connectivity Generic-VNF relates to it

Internet Profile Generic-VNF relates to it 
Metadatum EdgeRules only
Access ID

Metadata Entry

(under HSIA Internet Service Instance)

Metadatum EdgeRules only
Upstream Speed

Metadata Entry

(under HSIA CFS Service Instance)


Access Connectivity Generic-VNF relates to it

Internet Profile Generic-VNF relates to it
Metadatum EdgeRules only
Downstream Speed

Metadata Entry

(under HSIA CFS Service Instance)


Access Connectivity Generic-VNF relates to it

Internet Profile Generic-VNF relates to it
Metadatum EdgeRules only

OLT Name

Metadata Entry

(under HSIA Access Service Instance)


PON_UNI cp relates to it

OLT_NNI cp relates to it
Metadatum EdgeRules only
OLT PON port

Metadata Entry

(under HSIA Access Service Instance)


PON_UNI cp relates to it

Metadatum EdgeRules only
OLT PON slot

Metadata Entry

(under HSIA Access Service Instance)


PON_UNI cp relates to it

Metadatum EdgeRules only

CVLAN

Metadata Entry

(under HSIA Access Service Instance)


PON_UNI cp relates to it

Metadatum EdgeRules only
SVLAN

Metadata Entry

(under HSIA Access Service Instance)


OLT_NNI cp relates to it

Metadatum EdgeRules only
Expected ONT ID

Metadata Entry

(under HSIA Access Service Instance)


PON_UNI cp relates to it

Metadatum EdgeRules only
CPE Manufacturer

PNF object

equip-vendor: string

None
CPE Model

PNF object

equip-model: string

None
CPE Equipment Type

PNF object

equip-type: string

None
CPE Serial Number

PNF object

serial-number: string

None
CPE SW Version

PNF object

sw-version: string

None

Attachment Point

(Not a real BBS modeling property, since its constituent parts are captured in other model properties)

Logical Link object (bridged to the PNF object representing ONT)

link-name: string (will hold attachment point in the form of olt-name/pon-slot/pon-port e.g. olt1/1/1)

link-type: string (will hold literal value 'attachmentPoint')

None

(EdgeRule logical-link-to-pnf already exists)

Jira
serverONAP JIRA
serverId425b2b0a-557c-3c0c-b515-579789cceedb
keyAAI-2151


ONT NNI Port


Metadata Entry

(under HSIA Access Service Instance)


ONT_NNI cp relates to it

Metadatum EdgeRules only

OLT NNI Slot


Metadata Entry

(under HSIA Access Service Instance)


OLT_NNI cp relates to it
Metadatum EdgeRules only

OLT NNI Port


Metadata Entry

(under HSIA Access Service Instance)


OLT_NNI cp relates to it
Metadatum EdgeRules only

BNG Name

(Static configuration. Put into A&AI via a script)

Metadata Entry

(under HSIA Edge Service Instance)


BNG Generic-VNF relates to it

Metadatum EdgeRules only

BNG UNI Slot

(Static configuration. Put into A&AI via a script)

Metadata Entry

(under HSIA Edge Service Instance)


BNG-UNI cp relates to it

Metadatum EdgeRules only

BNG UNI Port

(Static configuration. Put into A&AI via a script)

Metadata Entry

(under HSIA Edge Service Instance)


BNG Generic-VNF relates to it

Metadatum EdgeRules only

Moving forward based on https://groups.io/g/onap-bbs/message/160
and https://groups.io/g/onap-bbs/message/161

Item 7. Add robot test cases

...