...
PlantUML Macro | ||
---|---|---|
| ||
@startuml participant OSS_BSS participant SO participant SO_NFVO participant Service_Designer participant CDS participant SDC participant ETSI_Catalog_Manager participant CIR participant SDNC participant MultiCloud participant VNFM participant VNF participant CNF autonumber group Design Time Service_Designer -> CDS : Design CBA Service_Designer -> SDC : Attach CBA to SDC Service CSAR SDC -> ETSI_Catalog_Manager : Distribute ETSI packages SDC -> SDNC : Distribute SDC Catalog SDC -> MultiCloud : Distribute SDC Catalog end group Run Time - Instantiation OSS_BSS -> SO : Request Instantiate SO -> SDNC : Get Resource Assignment SDNC -> CDS: Get resource assignment SO -> SO_NFVO : Request thru SOL005 (with instantiation parameter values) SO_NFVO -> VNFM : Request thru SOL003 (with instantiation parameter values) VNFM -> SO_NFVO : Request Grant CNF/VNF Resources SO_NFVO -> VNFM : Grant CNF/VNF Resources alt CNF VNFM -> CISM : CNF instantiation request else VNF VNFM -> VIM : VNF instantiation request end VNFM -> SO_NFVO : Instantiate Successful SO_NFVO -> SO : Instantiate Successful SO -> OSS_BSS : Instantiation Successful end group Run Time - Post Instantiation opt Configuration A SO_OSS_BSS -> SO : Request Configure SO->SO_NFVO : Request ModifyVNFInfo thru SOL005 SO_NFVO -> CDS_SS : Config-Assign action\n for saving CNF day-1 config SO_NFVO -> CDS_BP : Config-Deploy action\n for CNF config CDS_BP --> CDS_BP : Read config from DB CDS_BP -> SDNC : Invoke SDNC ODL alt CNF SDNC -> CNF: push config end opt Configuration B SO_NFVO -> VNFM : Request thru SOL003 VNFM -> VNF : Configuration Request\nthru Ve-Vnfm VNFM -> CNF : Configuration Request\nthru Ve-Vnfm VNFM -> SO_NFVO : Configuration Response end end else VNF SDNC -> VNF: push config end SO_NFVO -> SO : Configuration Successful SO -> OSS_BSS : Configuration Successful end opt Configuration B OSS_BSS -> SO : Request Configure SO->SO_NFVO : Request ModifyVNFInfo\nthru SOL005 SO_NFVO -> VNFM : Request ModifyVNFInfo\nthru SOL003 alt VNF VNFM -> VNF : Configuration Request\nthru Ve-Vnfm else CNF VNFM -> CNF : Configuration Request\nthru Ve-Vnfm end VNFM -> SO_NFVO : Configuration Response SO_NFVO -> SO : Configuration Successful SO -> OSS_BSS : Configuration Successful end opt Configuration C OSS_BSS -> SO : Request Configure SO -> CDS_SS : Config-Assign action\n for saving CNF day-1 config SO -> CDS_BP : Config-Deploy action\n for CNF config CDS_BP --> CDS_BP : Read config from DB CDS_BP -> SDNC : Invoke SDNC ODL alt CNF SDNC -> CNF: push config else VNF SDNC -> VNF: push config end SO -> OSS_BSS : Configuration Successful end end @enduml |
PoC Configuration Sequence
...