This section refers to Instantiation of a Deployed control loop. A client, in this case CLAMP (potentially DCAEMOD, etc in the future) will render the deployed control loops allowing selection of a particular control loop to be instantiated. User will then provide the configurations needed to instantiate the selected control loop which will be sent onto the CL_Instance_Control Service. The service will then distribute the configurations to DmaaP topic. Participants (agents) will pull the event containing the config and pick out their control loop components to be instantiated and start/set up those particular components. CL_Instance_Control Service will be waiting for a response back from all participants involved in the instantiation of the control loop, in regards to the state of instantiation. In successful response case the service will store the CL Instance LCM data into the runtime DB as well as providing a message back to the client of the successful instantiation. In failure to receive the response case, a timeout will be called, which will result in a teardown event being sent to DmaaP. The participants will then receive the event and proceed to teardown the components that were instantiated or check that they have failed to instantiate in the first place and send a Teardown ACK back to the CL_Instance_Control Service. No CL Instance LCM data will be stored and a message indicating failure to instantiate the CL along side with the error will be sent back to the client (CLAMP).

...