Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

AttributeQualifierCardinalityContentDescription
idM1StringThe identifier of this extCpdData
descriptionM1StringDescribes the service exposed.
virtualLinkRequirementM1..NStringRefers in an abstract way to the network or multiple networks that the ExtCpd shall be exposed on (ex: OAM, EndUser, backhaul, LI, etc). The intent is to enable a network operator to take decision on to which actual VPN to connect the extCpd to. NOTE 1.
networkInterfaceRealizationRequirementsM0..1datatype.networkInterfaceRealizationRequirementsDetails container implementation specific requirements on the NetworkAttachmentDefinition to . See NOTE 2 & 3.
inputParamMappingsM0..1datatype.extCpd.ParamMappingsInformation on what parameters that are required to be provided to the deployment tools for the asdExtCpd instance.
resourceMappingM0..1StringKubernetes API resource name for the resource manifest as specified e.g. in helm.chart for the service, ingress or pod resource declaring the network interface. Enables, together with knowledge on namespace, the orchestrator to lookup the runtime data related to the extCpd.

...

AttributeQualifierCardinalityContentDescription
trunkModeM0..1”false” | ”true”If not present or  set to”false”, means that this interface shall connect to single network. If set to ”true” then the network interface shall be a trunk interface (connects to multiple VLANS).
ipamM0..1"infraProvided", "orchestrated", "userManaged"The default value ("infraProvided") means that the CNI specifies how IPAM is done and assigns the IP address to the pod interface. 
interfaceType​M0..1

"kernel.netdev", "direct.userdriver", "direct.kerneldriver", "direct.bond", "userspace

This attribute is applicable for passthrough and memif interfaces. Value default value is ”kernel.netdev”.​ 
interfaceOptionsM0..N

"virtio",
"memif"

Alternative vNIC configurations the network interface is verified to work with.

interfaceRedundancyM0..1"infraProvided", "activePassiveBond", "activeActiveBond", "activePassiveL3", "activeActiveL3",
 ”bondCni”,
"Left", "Right"

”infraProvided” means that the application sees one vNIC but that the infrastruture provides redundant access to the network via both switch planes. ”Left” and ”right” indicates a vNIC connected non-redundantly to the network via one specific (left or right) switchplane. All other attributes indicates a mated vNIC pair in the Pod, one connecting to the network via left switchplane and the other connecting to the network via the right switchplane, and with application using them together as a redundant network interface using a particular redundancy method that need to be accomodated in the node infrastructure.
"activeActiveBond": The bonded left/right links must be part of a multi-chassis LAG in active-active mode
"activePassiveBond": Interfaces bonded in active-passive mode in the application with move of bond MAC address. No specific requirements on DC fabric.
"activePassiveL3":  Move of application IP address
"activeActiveL3": Anycast/ECMP
”bondCni” ; the mated pair network interfaces are used via a 3rd bond cni based network interface.

nicOptionsM0..1N"examples": ["i710", "mlx-cx5v"]

nics a direct user space driver the application is verified to work with. Allowed values from ETSI registry.

...

1[String]1..N, asdExtCpd deployment artifact input parameters through which the orchestrator can configure the corresponding network annotation in the pod manifest with references to the NAD(s) to be used for creating the network interface
AttributeQualifierCardinalityContentDescription
loadbalancerIPM0..1String

When present, this attribute specifies the name of the deployment artifact input parameter through which the orchestrator can configure the loadbalancerIP parameter of the K8s service or ingress controller that the ExtCpd represents.

externalIPsM0..1NString

When present, this attribute specifies the name of the deployment artifact input parameter through which the orchestrator can configure the extermalIPs parameter of the K8s service or ingress controller, or the pod network interface annotation, that the ExtCpd represents. The param name and provided IP address(es) value will be passed to the deployment tool when deploying the DeploymentArtifacts. Note 1

nadNameM0..NString
Note 2, Note 3
These attributes specifies, for an ExtCpd respesenting a secondary network interface, the name(s) of the network attachment definitions (NADs) the orchestrator has created as base for the network interface the ExtCpd represents.
It is expected that the NADs themselves have been created prior to the deployment of the deployment artifacts.
nadNamespaceM0..1StringSpecifies, for an asdExtCpd respesenting a secondary network interface, the namespace where the NADs are located.
Attribute may be omitted if the namespace is same as the application namespace. 

Note 1: When the asdExt Cpd represent a networkRedundant/mated-pair of sriov interfaces, there are references to 2 or 3 related NADs needed to be passed, lwhile while for other interface types only one NAD reference is needed to be passed.

...