10. Run `vcpe.py infra`
11. Make sure sniro configuration is run as part of the above step.
12. Install curl command in sdnc-sdnc container
13. Run healthcheck-k8s.sh to check connectivity from sdnc to brg and gmux. If healthcheck-k8s.sh fails, check /opt/config/sdnc_ip.txt to see it has the SDNC host ip correctly. If you need to change SDNC host ip, you need to clean up and rerun `vcpe.py infra`. Also verify tap interfaces tap-0 and tap-1 are up by running vppctl with show int command. If tap interfaces are not up, use vppctl tap delete tap-0 and tap-1 and vppctl restartthen run `/opt/bind_nic.sh` followed by `/opt/set_nat.sh`.
Code Block | ||||
---|---|---|---|---|
| ||||
root@zdcpe1cpe01brgemu01-201812261515:~# vppctl tap delete tap-0 Deleted. root@zdcpe1cpe01brgemu01-201812261515:~# vppctl tap delete tap-1 Deleted. root@zdcpe1cpe01brgemu01-201812261515:~# vppctl restart exec error: Misc /opt/bind_nic.sh root@zdcpe1cpe01brgemu01-201812261515:~# /opt/set_nat.sh root@zdcpe1cpe01brgemu01-201812261515:~# vppctl show int Name Idx State Counter Count GigabitEthernet0/4/0 1 up tx packets 12 tx bytes 3912 local0 0 down tap-0 2 up rx packets 5 rx bytes 410 drops 7 ip6 1 tap-1 3 up rx packets 1 rx bytes 70 drops 7 ip6 1 |
...