Testing Information

Showcase VNF

Test Environment

Integration Team Liasion

vDNSSB04, SB02

Current Status

  1. Just beginning test planning
  2. Testing has not yet begun

Summary Testing Status

Goal

Test Cases

Status

Auto Scale Out101-112, 301-303, 501-507

COMPLETE

Manual Scale Out Enhancements201, 401-407, 601-604

COMPLETE

Manual Scale Out works, but requires a Postman call to SO instead of using VID

Controller Type402

NOT YET STARTED



End to End Flow to be Tested

























Test Cases and Status

Design Time

SDC

#

Test Case

Status

101 Create License Model in SDC 

 COMPLETE

102Create Vendor Software Product (VSP) in SDC

 COMPLETE

103Create Service Model by selecting the onboarded VSP

 COMPLETE

104 Attach the DCE Blueprint to the Service Model

 COMPLETE

105Service Model Distribution (AAI, SO, SDNC, CLAMP)

 COMPLETE

CLAMP

#

Test Case

Status

106User Permissions from AAF

COMPLETE

107Create Closed Loop for Scale Out

COMPLETE

108Create Scale Out Policy (Operational Policy)

COMPLETE

109Create Guard Policies

COMPLETE

110Specify the Path Resolution of the configScaleOut Parameters

COMPLETE

111Deploy Closed Loop to DCAE

COMPLETE

112Push Scale Out Policy

COMPLETE

113Push Guard Policy

COMPLETE

114Nexus to load original Operational policy and update with guard policies

COMPLETE

115Drools (Policy): BRMS GW to send notification to Drools about new operational policy in Nexus

COMPLETE

116DCAE to get configuration policy from Policy

COMPLETE

Run Time

Manual Scaling

#

Test Case

Status

201VID send Manual Scale Out Request to SO via REST

FAILED

SO must be called using Postman rather than VID.

Closed Loop Scaling

#

Test Case

Status

301

DCAE Sends Policy a Scale Out Event when threshold is crossed

COMPLETE

302Policy checks Guard policies to see if it should tell SO to Scale

COMPLETE 

303Policy Sends Scale Out Request to SO

COMPLETE

Healthcheck

#

Test Case

Status

401SO retrieves VNF Level IP Address from AAI

COMPLETE

402SO retrieves Controller_Type from internal lookup table

COMPLETE

403SO Sends Healthcheck request to DMaaP

COMPLETE

404APPC/SDNC picks up Healthcheck request from DMaaP

COMPLETE

405APPC/SDNC sends RESTCONF Healthcheck to vLB

COMPLETE

406vLB returns Healthcheck status to APPC/SDNC

COMPLETE

407SO receives Healtcheck results

COMPLETE

Instantiation

#

Test Case

Status

501SO sends CreateVF-Module to AAI

COMPLETE

502SO Sends VFModule Resource Assignment Request to SDNC

COMPLETE

503SDNC does Heat and Resource Assignment

COMPLETE

504SDNC writes information to AAI

COMPLETE

505SO executes Create VF_Module via Heat 

COMPLETE

506New instance of vDNS component is created

COMPLETE

507So updates AAI with Heatstack ID

COMPLETE

508Create CDS CBA package using the CDS UI 

COMPLETE

509Attach a CDS CBA Artifact to the VNF resource 

COMPLETE

Configuration

#

Test Case

Status

601

Request Configuration Values from SDNC

COMPLETE

602SDNC Returns Configuration Values

COMPLETE

603SO Builds the ConfigScaleOut Payload

COMPLETE

604SO sends ConfigScaleOut to controllers via DMaaP

COMPLETE

605Controllers receive ConfigScaleOut from SO via DMaaP

COMPLETE

606Controllers gather required configuration information

COMPLETE

607Controllers configure VNF 

COMPLETE

Healthcheck

#

Test Case

Status

701Healthcheck is properly run after scaling is complete

COMPLETE