V00001: WindRiver OpenStack VIM Resource Onboarding

Test Case IdV00001
Test Case NameWindRiver OpenStack VIM Resource Onboarding
DescriptionWindRiver OpenStack VIM Resource Onboarding
Release
Preconditions
  1. The WindRiver OpenStack VIM is configured with tenant information and provider networks
  2. The WindRiver OpenStack VIM services (console, auth, neutron, image, glance, etc) are accessible from ONAP by IP
Testing Steps
  1. Add VIM from ONAP GUI with VIM location information, tenant authentication information
  2. VIM default service url can be configured based on real VIM settings
Expected Results
  1. VIM resource is onboarded successfully
  2. Tenant authentication information is stored successfully
Actual Results
Conclusion (Pass/Fail)
Testing Lab
Tester Name


V00002: WindRiver OpenStack 2nd VIM Resource Onboarding

Test Case IdV00002
Test Case NameWindRiver OpenStack 2nd VIM Resource Onboarding
DescriptionThis is to test multi VIM support
Release
Preconditions
  1. The first WindRiver OpenStack VIM has been successfully onboarded
  2. A new WindRiver OpenStack VIM is configured with tenant information and provider networks
  3. The new WindRiver OpenStack VIM services (console, auth, neutron, image, glance, etc) are accessible from ONAP by IP
Testing Steps
  1. Add the new VIM from ONAP GUI with VIM location information, tenant authentication information
  2. The new VIM default service url can be configured based on the new VIM settings
Expected Results
  1. The new VIM resource is onboarded successfully
  2. The new VIM Tenant authentication information is stored successfully
Actual Results
Conclusion (Pass/Fail)
Testing Lab
Tester Name


V00003: VMWare OpenStack VIM Resource Onboarding

Test Case IdV00003
Test Case NameVMWare OpenStack VIM Resource Onboarding
DescriptionVMWare OpenStack VIM Resource Onboarding
Release
Preconditions
  1. The VMWare OpenStack VIM is configured with tenant information and provider networks
  2. The VMWare OpenStack VIM services (console, auth, neutron, image, glance, etc) are accessible from ONAP by IP
Testing Steps
  1. Add VIM from ONAP GUI with VIM location information, tenant authentication information
  2. VIM default service url can be configured based on real VIM settings
Expected Results
  1. VIM resource is onboarded successfully
  2. Tenant authentication information is stored successfully
Actual Results
Conclusion (Pass/Fail)
Testing Lab
Tester Name


V00004: VMWare OpenStack 2nd VIM Resource Onboarding

Test Case IdV00004
Test Case NameVMWare OpenStack 2nd VIM Resource Onboarding
DescriptionThis is to test multi VIM support
Release
Preconditions
  1. The first VMWare OpenStack VIM has been successfully onboarded
  2. A new WindRiver OpenStack VIM is configured with tenant information and provider networks
  3. The new WindRiver OpenStack VIM services (console, auth, neutron, image, glance, etc) are accessible from ONAP by IP
Testing Steps
  1. Add the new VIM from ONAP GUI with VIM location information, tenant authentication information
  2. The new VIM default service url can be configured based on the new VIM settings
Expected Results
  1. The new VIM resource is onboarded successfully
  2. The new VIM Tenant authentication information is stored successfully
Actual Results
Conclusion (Pass/Fail)
Testing Lab
Tester Name


V00005: Data Center Gateway Resource Onboarding

Test Case IdV00005
Test Case NameData Center Gateway Resource Onboarding
DescriptionThis is part of WAN setup testing. Each data center has its own gateway and controlled by local SDN controller
ReleaseAmsterdam
Preconditions
  1. VIMs from the same vendor have been successfully onboarded
  2. Each DC gateway has been manually installed and configured correctly
  3. Each DC gateway local controller has been manually installed and configured correctly
Testing Steps
  1. Onboard each DC gateway local controller from ONAP GUI (need to confirm which ONAP GUI supports SDN local controller - OOM or UsecaseUI?) with the needed information (IP, port, authentication information, etc)
Expected Results
  1. The DC local controller is onboarded successfully
  2. The DC local controller information is stored successfully
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Tester Name


V00006: WAN PE Resource Onboarding

Test Case IdV00006
Test Case NameWAN PE Resource Onboarding
DescriptionThis is part of WAN setup testing. There are at least two PEs in the network, controlled by one SDN WAN controller
ReleaseAmsterdam
Preconditions
  1. Each PE router has been manually installed and configured correctly
  2. SDN WAN controller has been manually installed and configured correctly
Testing Steps
  1. Onboard SDN WAN controller from ONAP GUI (need to confirm which ONAP GUI supports SDN local controller - OOM or UsecaseUI?) with the needed information (IP, port, authentication information, etc)
Expected Results
  1. The SDN WAN controller is onboarded successfully
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Tester Name


V00007: VoLTE VNFs Onboarding

Test Case IdV00007
Test Case NameVoLTE VNFs Onboarding
DescriptionVNFD csar files need to be onboarded one by one
ReleaseAmsterdam
Preconditions
  1. All vEPC and vIMS VNFD csar files can pass VNFSDK checking
Testing Steps
  1. Use SDC to onboard vEPC VNFD csar files one by one
  2. Use SDC to onboard vIMS VNFD csar files one by one
Expected Results
  1. vEPC csar files are onboarded successfully
  2. vIMS csar files are onboarded successfully
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00008: vEPC Service Creation

Test Case IdV00008
Test Case NamevEPC Service Creation
DescriptionThis creates vEPC service
ReleaseAmsterdam
Preconditions
  1. All vEPC VNFD csar files can pass VNFSDK checking
  2. All VNFs images files have been uploaded manually into ONAP
Testing Steps
  1. Use SDC to create vEPC service with the following VNFs
    1. vSPGW
    2. vEPDG
    3. vPCRF
    4. vHSS
    5. vMME
  2. As part of vEPC service composition, create Virtual Links (VL) to connect the VNFs together according to vEPC service design
Expected Results
  1. vEPC service is created successfully
  2. vnfmInfo is correctly pointed to vendor's VNFM
  3. vEPC service is successfully stored in catalog
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00009: vIMS Service Creation

Test Case IdV00009
Test Case NamevIMS Service Creation
DescriptionThis test creates vIMS service which includes VNFs and Network Service
ReleaseAmsterdam
Preconditions
  1. All vIMS VNFs csar files can pass VNFSDK checking
  2. All VNFs images files have been uploaded manually into ONAP
Testing Steps
  1. In SDC create vIMS service with the following VNFs
    1. vPCSCF
    2. vI/SCSCF
    3. vTAS
  2. As part of vIMS service composition, create Virtual Links (VL) to connect the VNFs together according to vIMS service design
Expected Results
  1. vIMS service is created successfully
  2. vnfmInfo is correctly pointed to vendor's VNFM
  3. vIMS service is successfully stored in catalog
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00010: WAN Service Creation

Test Case IdV00010
Test Case NameWAN Service Creation
DescriptionThis test creates WAN service
ReleaseAmsterdam
Preconditions
  1. All PNFs (PE, DC gateway) resources have been onboarded
  2. All required network connection types (VLAN, MPLS L3 VPN, VXLAN, etc) are defined by SDC
Testing Steps
  1. In SDC create WAN service
  2. In service composition, pull in 2 PEs
  3. In service composition, pull in 2 data center gateways
  4. Create underlay network as following:
    1. DC GW1 → PE1 as vlan
    2. DC GW2 → PE2 as vlan
    3. PE1 → PE2 as MPLS L3 VPN
  5. Create overlay network DC GW1 → DC GW2 as VXLAN
Expected Results
  1. Underlay WAN network created successfully
  2. Overlay WAN network create successfully
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00011: VoLTE Service Creation

Test Case IdV00011
Test Case NameVoLTE Service Creation
DescriptionThis test creates VoLTE service. To workaround SDC limitation on nested service support, in R1 we create separate dummy VNFs in VoLTE service, and link those VNFs to vEPC, vIMS and WAN services
ReleaseAmsterdam
Preconditions
  1. vEPC service has been created
  2. vIMS service has been created
  3. WAN service has been created
  4. All required ONAP artifacts (DG, DCAE template, Holmes blueprint, SO workflow, etc) have been designed
Testing Steps
  1. In SDC onboard the dummy VNF, called EPC, which links to vEPC service using ID property. Set the VNF controllerInfo to VFC
  2. Onboard the dummy VNF, called IMS, which links to vIMS service using ID property. Set the VNF controllerInfo to VFC
  3. Onboard the dummy VNF, called WAN, which links to WAN service using ID property. Set the VNF controllerInfo to SDNC
  4. Compose VoLTE service with EPC, IMS and WAN dummy VNFs
  5. Upload DG artifact in SDC
  6. Upload DCAE template
  7. Upload SO workflow
  8. Test and approve VoLTE service
  9. Distribute VoLTE service
Expected Results
  1. VoLTE service is created successfully
  2. VoLTE service is stored in catalog
  3. Service Creation event is sent via DMaaP
  4. Other modules (SO, VID, Usecase UI, CLAMP, VID, etc) receives the event
  5. VoLTE service is retrieved from SDC catalog by other modules
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


V00012: Closed Loop Configuration

Test Case IdV00012
Test Case NameClosed loop configuration
DescriptionThis test uses CLAMP to configure closed loop for VoLTE
ReleaseAmsterdam
Preconditions
  1. DCAE template has been imported (R1 SDC doesn't support DCAE template design)
  2. Holmes blueprint has been imported
  3. Holmes correlation rules have been defined
Testing Steps
  1. In CLAMP, choose which VNF and event to monitor
  2. Bring up CLAMP configuration policy GUI and copy Holmes correlation rules in it
  3. Bring up CLAMP provisional policy GUI and define reboot provisional policy
  4. Save the configuration
Expected Results
  1. Closed loop template and blueprint for Holmes are distributed to DCAE
  2. Configuration policy has been distributed to DCAE
  3. Provisional policy has been distributed to Policy engine
Actual Results
Conclusion (Pass/Fail)
Testing LabCMCC OpenLab
Testing Date
Tester Name


- Instantiation: VNFs are deployed in edge and core data centers successfully. Intra data center network, underlay and overlay WAN network cross the two data centers are setup correctly

- Auto-healing for VIM event: DCAE VES collector receives the VNF event from VIM, and forwards it to Holmes. Holmes does the correlation and generates signature event and sends to  Policy. Then auto-healing policy is triggered and proper actions are taken to mitigate the situation

- Auto-healing for VNF event: When alarm is generated by VNF, VFC will receive the alarm via vendor’s EMS and forwards to DCAE VES collector. The DCAE collector will then forward  alarm to Holmes via DMaaP. Holmes does the alarm correlation and sends signature event to Policy. Finally the auto-healing policy is triggered and proper actions are taken to mitigate the situation

- Service termination: When user terminates the VoLTE service, VNFs and related resource for the service are properly removed, and WAN connectivity between the two data center is  also removed successfully.