This page is used for discussing attributes to be added into to the information model.

Note: the attribute marked as blue is expected for moving into the clean version

IM Table Format

attribute table

attribute namecardinalitydata typeconstraintdescriptionproviderconsumernote
name of the attributeallowed range of occurrence, format: an exact number, or min...maxdata type of the attributeusage constraintdescription of the attributewho provides the value of the attributewho consumes the value of the attributenote, reference, comment, etc...
(example)






vnfdInvariantId1

invariant identifier of the VNF modelvendorSDC, AAI?SDC: invariantUUID
vnfName0..1

name of the VNFvendorSDC, AAI?SDC: nf_naming, ETSI IFA011v231: vnfProductName
vnfdVersion1

version of the VNF modelvendorSDC, AAI?SDC: version, ETSI IFA011v231: vnfdVersion

relationship table

class namerelationshipsource/targetcardinality
name of the classcategory of the relationship, e.g., association, generalizationwhether the described class is source or target of this relationshipallowed range of occurrence, format: an exact number, or min...max
(example)


VnfcDescassociationtarget1..N
VnfVlDescassociationtarget1..N


NFC/VNFC Run Time Model

AAI (aai_schema_v11 vnfc)ECOMP IM (VNFC Instance)ETSI IFA008 (VnfcInfo)CommentDescription
orchestration-status
vnfcState

Xu Yang: Is it the same as vnfcState (i.e., start or stop)?
James Forsyth: Used for lifecycle management.  We don't know what vnfcState is.

Xu Yang: vnfcState describes the state of a VNFC instance, possible values are: STARTED, STOPPED. STARTED means the VNFC instance is up and running, and STOPPED means the VNFC instance has been shut down (but not terminated/deleted). Similar to the VM power on/off concept.

Orchestration status of this VNF, mastered by APP-C
group-notation

Xu Yang: need further clarification on how this attribute is used
James Forsyth: In some applications, a two or more VMs or VNFCs is referred to by a name, and group-notation represents the name.  Might want to use instance-group to replace this over time.

Group notation of VNFC
model-version-id


the SDC model version for this resource model
relationship-listassociation (VM, Docker, LXC)

AAI: relationship with vserver, vf-module and generic-vnf


NFC/VNFC Design Time Model

SDC (abstract.nodes.VFC)ECOMP IM (VNFCCatalogItem)ETSI IFA011 (VDU/VduProfile)CommentDescription
Vm_type_tag


Mandatory String property that indicates the vm-type as was defined by vendor


bootOrder

The key indicates the boot index (lowest index defines highest boot priority). The Value references a descriptor from which a valid boot device is created e.g. VirtualStorageDesc from which a VirtualStorage instance is created.



nfviConstraint

Describes constraints on the NFVI for the VNFC instance(s) created from this Vdu.



configurableProperties

Describes the configurable properties of all VNFC instances based on this VDU.


VNF Run Time Model

AAI (generic_vnf)ECOMP IM (VNF instance)ETSI IFA007 (VnfInfo)CommentDescription
orchestration-status

Xu Yang: only used by SO?
James Forsyth: Used by anyone who wants to check it, set by SO

Xu Yang: could you elaborate more on the valid values and their meaning?

Orchestration status of this VNF, used by SO.
management-option

Xu Yang: Need clarification on how this attribute is used.
James Forsyth: indicates who manages a specific resource, whether it's the service provider or a customer

identifier of managed by service provider or customer
ipv4-loopback0-address

Xu Yang: same as above
James Forsyth: Not mandatory, and it can be applicable for all kinds of VNFs, depending on the requirements of the VNF

v4 Loopback address
nm-lan-v6-address

Xu Yang: same as above
James Forsyth: Not mandatory, and it can be applicable for all kinds of VNFs, depending on the requirements of the VNF

v6 Loopback address
vcpu

Xu Yang: only used by uCPE?
James Forsyth: Yes

number of vcpus ordered for this instance of VNF, used for VNFs with no vservers/flavors, to be used only by uCPE
vcpu-units

Xu Yang: only used by uCPE?
James Forsyth: Yes

units associated with vcpu, used for VNFs with no vservers/flavors, to be used only by uCPE
vmemory

Xu Yang: only used by uCPE?
James Forsyth: Yes

number of GB of memory ordered for this instance of VNF, used for VNFs with no vservers/flavors, to be used only by uCPE
vmemory-units

Xu Yang: only used by uCPE?
James Forsyth: Yes

units associated with vmemory, used for VNFs with no vservers/flavors, to be used only by uCPE
vdisk

Xu Yang: only used by uCPE?
James Forsyth: Yes

number of vdisks ordered for this instance of VNF, used for VNFs with no vservers/flavors, to be used only uCPE
vdisk-units

Xu Yang: only used by uCPE?
James Forsyth: Yes

units associated with vdisk, used for VNFs with no vservers/flavors, to be used only by uCPE
resource-version

Xu Yang: Is it used internally in AAI? can be omitted in the general model.
James Forsyth: It's used internally in AAI to enforce concurrency control, other systems use it to pass to AAI on updates and delete operations

Used for optimistic concurrency.  Must be empty on create, valid on update and delete.
model-customization-id


captures the id of all the configuration used to customize the resource for the service
as-number

Xu Yang: Please clarify the usage of this attribute.
James Forsyth Has to do with routing, not applicable for all VNFs

as-number of the VNF
regional-resource-subzone


Regional way of organizing pservers, source of truth should define values
nf-type

Xu Yang: What's the difference between vnf-type and nf-type?
James Forsyth - we are getting rid of vnf-type and replacing with nf-type, nf-function, and nf-role

Generic description of the type of NF
nf-roleNetworkRole

role in the network that this model will be providing
selflink

Xu Yang: what controller?
James Forsyth: Not sure if it's being populated

Path to the controller object
vlan-id-outer

Xu Yang: only used by VCE?
James Forsyth Not sure

Temporary location for S-TAG to get to VCE
nm-profile-name


Network Management profile of this VNF
relationship-list

Xu Yang: Is the description correct?
James Forsyth - The edge rules has the exhaustive list of possible relationships for generic-vnf

relationship with l-interface, availability-zone, lag-interface, l3-network, pserver, vserver, service-instance, vf-module, volume-group, vnfc and logical-link

l-interfaces


logical interfaces
lag-interfaces


Collection of link aggregate interfaces
vf-modules


a deployment unit of VNFCs
licenses


license information
entitlements


entitlement information

HomingPolicy

Reference to VNF-level homing policy that ECOMP will use when VNF deployment target node is auto-selected

TargetNodePrompt

"Y" indicates operator-supplied VNF instance target deployment node required. Present prompt to operator: "Enter target node for deployment of this VNF instance"

"N" indicates that the target deployment node for this VNF instance will be auto-selected by ECOMP

VLAN Range Plan

Identifies the VNF-level VLAN Range Plan that must be used by ECOMP to assign VLAN tags to an instance of this VNF type

VNF Name Prompt

"Y" indicates operator-supplied VNF name required. Present prompt to operator: "Enter the name for this VNF instance"

"N" indicates that the name for the VNF instance will be auto-generated by ECOMP

VNF Naming Policy

Reference to VNF-level naming policy that ECOMP will use when VNF-level name is auto-generated

VNF Network Tag

Must correlate to the set of defined “network-role” identifiers from the associated HEAT templates


metadata

Additional VNF-specific metadata describing the VNF instance.



extension

VNF-specific attributes that affect the lifecycle management of this VNF instance by the VNFM, or the lifecycle management scripts.


VNF Design Time Model

ONAP VNFD IM - based on IFA011 v231.docx

ONAP VNFD IM draft based on IFA011 v231 format and models: for discussion


ExternalVirtualLink Design Time Mode

SDC
(extVL)
AAI ECOMP IMETSI IFA014
(virtualLinkDesc)
CommentsConfirmedDescription
invariantUUID



invariantUUIDConstant identifier of the external virtual link
UUID

virtualLinkDescId
vldIdVersioned identifier of the external virtual link
customizationUUID


maopeng zhang

is the resource instance referred to the run-time resource instance? If it is in the run-time, why is it in the design time?


Identifier of the resource instance (uuid of the specific use of the resource model in this service). This identifier is regenerated whenever a user makes a change on the resource instance.

version

virtuaLinkDescVersion
versionThe version of the external virtual link
name



nameThe name of the external virtual link
description



descriptionThe description of the external virtual link
type




The type of resource. Resource type can be either VF, VFC, VFCMT, CP or VL.
category




Category of the resource
subcategory




Sub-category of the resource
resourceVendor




specifies the vendor providing this asset
resourceVendorRelease




specifies the release version given by the vendor (no exact correlation to the version of the asset in the SDC catalog)
resourceVendorModelNumber




Metadata of resources (VFs, VFCs, PNF) will include new field resourceVendorModelNumber. The value for this field is the part number defined by the vendor, e.g. “MX960”.

network_type



network_typespecifies the nature of the physical network in the underlying cloud infra-structure. Examples are flat, vlan, gre or vxlan. For flat and vlan types, physical_network should be provided too.
network_role




Unique label that defines the role that this network performs.   example: vce oam network, vnat sr-iov1 network
network_scope




Uniquely identifies the network scope. Valid values for the network scope   includes: VF - VF-level network. Intra-VF network which connects the VFCs (VMs) inside the VF. SERVICE - Service-level network. Intra-Service network which connects  the VFs within the service GLOBAL - Global network which can be shared by multiple services
network_technology




ECOMP supported network technology
network_ecomp_naming





network_homing





network_assignments





provider_network





network_flows





vendor

vitualLinkDescProvider


vl_name


same with the name

ip_version



ip_versionThe IP version of the requested network.
cidr



cidrThe cidr block of the requested network.
start_ip



start_ipThe IP address to be used as the 1st one in a pool of addresses derived from the cidr block full IP range.
end_ip



end_ipThe IP address to be used as the last one in a pool of addresses derived from the cidr block full IP range.
gateway_ip



gateway_ipThe gateway IP address.
network_name



network_nameAn Identifier that represents an existing Network instance in the underlying cloud infrastructure - OR - be used as the name of the new created network.
network_id



network_idAn Identifier that represents an existing Network instance in the underlying cloud infrastructure. This property is mutually exclusive with all other properties except network_name.
segmentation_id



segmentation_idA segmentation identifier in the underlying cloud infrastructure (e.g., VLAN id, GRE tunnel id). If the segmentation_id is specified, the network_type or physical_network properties should be provided as well.
physical_network



physical_networkidentifies the physical network on top of which the network is implemented, e.g. physnet1. This property is required if network_type is flat or vlan.
 dhcp_enabled



 dhcp_enabledIndicates the TOSCA container to create a virtual network instance with or without a DHCP service.



testAccess





virtualLinkDf





ConnectivityType
(layerProtocol,flowPattern)






security



ExternalVirtualLink Run Time Model

AAI
(l3-network)
ECOMP IM

ETSI IFA013

(VirtualLink)

CommentsConfirmedDescription
network-id
nsVirtualLinkInstanceId
virtualLinkInstanceId
network-name
description
description
network-role




network-technology




neutron-network-id
ResourceHandle
(vimId,resourceProviderId,resourceId)



is-bound-to-vpn 




service-id
nsInstanceId
componentInstanceId
network-role-instance




resource-version




orchestration-status




heat-stack-id




mso-catalog-key




contrail-network-fqdn




model-invariant-id


invariantUUID
model-version-id


UUID
persona-model-version


version
model-customization-id




widget-model-id




widget-model-version




physical-network-name




is-provider-network 




is-shared-network 




is-external-network 




selflink


selfLink
operational-status


status


nslinkport