The reference between physical and traffic/communication view is provided by physical-port-reference parameter. Further reference: - SDNC-774Getting issue details... STATUS .
The example shows the parameter, that is part of the ltp parameters and is referencing one or more "equipment" objects, identified by uuid.
A more complete example as XML file can be found here: https://github.com/Melacon/WirelessTransportEmulator/blob/master/NetconfServerSimulator/xmlNeModel/equipment.xml.
For creating a helpfull information for the user, the equipment/name and equipment/label should be used.
The important points are shown in the XML parts:
<network-element> ..something.. <ltp> <uuid>LTP-MWPS-TTP-01</uuid> ..something.. <client-ltp>LTP-MWS-TTP-01</client-ltp> <!-- SDNC-774: list contains 0 .. N references to related "equipment" objects, identified by uuid --> <physical-port-reference>a2.module-1.65.1.2</physical-port-reference> <lp> ..something.. </lp> </network-element> <mw-air-interface-pac xmlns="urn:onf:params:xml:ns:yang:microwave-model"> <layer-protocol>LP-MWPS-TTP-01</layer-protocol> <air-interface-capability> ..something.. </air-interface-capability> </mw-air-interface-pac> <equipment> <uuid>a2.module-1.65.1.2</uuid> <name> <value-name>name</value-name> <value>a2.module attached to Port 1.2 of Subrack connected at WS Shelf, Slot 6, Port 5</value> </name> <label> <value-name>label</value-name> <value>MWR#65Ch#1/a2.moduletraff</value> </label> </equipment>